pitaszek
|
Wpisanie do konsoli HA załatwia temat błędów w logu:
mosquitto_pub -h 192.168.1.204 -p 1893 -u LOGIN -P HASŁO -t "homeassistant/sensor/ecoal_furnace/custom_1@temp/config" -n -r mosquitto_pub -h 192.168.1.204 -p 1893 -u LOGIN -P HASŁO -t "homeassistant/sensor/ecoal_furnace/custom_2@vtemp/config" -n -r mosquitto_pub -h 192.168.1.204 -p 1893 -u LOGIN -P HASŁO -t "homeassistant/sensor/ecoal_furnace/custom_21@vtemp/config" -n -r mosquitto_pub -h 192.168.1.204 -p 1893 -u LOGIN -P HASŁO -t "homeassistant/sensor/ecoal_furnace/custom_22@vtemp/config" -n -r |
|||
|
|
||||
|
pitaszek
|
Było tak:
scan_interval: 30 resource: http://192.168.1.100/getregister.cgi?device=0&tzew_value&fuel_level&next_fuel_time&tryb_auto_state&tcwu_value&tkot_value&twew_value&act_dm_speed&tpow_value&tsp_value&1@temp&21@vtemp sensor: ### Odczyt temperatury zewnętrznej - name: eCoal Temperatura zewnętrzna unique_id: ecoal_temperatura_zewnetrzna value_template: {{ value_json["cmd"]["device"]["reg"][0]["@v"] }} unit_of_measurement: "°C" ### Odczyt poziomu paliwa - name: eCoal Poziom paliwa unique_id: ecoal_poziom_paliwa value_template: {{ value_json["cmd"]["device"]["reg"][1]["@v"] }} unit_of_measurement: "%" ### Odczyt daty następnego zasypu - name: eCoal Data zasypu unique_id: ecoal_data_zasypu value_template: {{ value_json["cmd"]["device"]["reg"][2]["@v"] | int | timestamp_custom("%Y-%m-%d %H:%M") }} ### Odczyt stanu pracy kotła - name: eCoal Tryb pracy kotła unique_id: ecoal_tryb_pracy_kotla value_template: {{ value_json["cmd"]["device"]["reg"][3]["@v"] }} ### Odczyt temperatury CWU - name: eCoal Temperatura CWU unique_id: ecoal_temperatura_cwu value_template: {{ value_json["cmd"]["device"]["reg"][4]["@v"] }} unit_of_measurement: "°C" ### Odczyt temperatury kotła - name: eCoal Temperatura kotła unique_id: ecoal_temperatura_kotla value_template: {{ value_json["cmd"]["device"]["reg"][5]["@v"] }} unit_of_measurement: "°C" ### Odczyt temperatury wewnętrznaj - name: eCoal Temperatura wewnętrzna unique_id: ecoal_temperatura_wewnetrzna value_template: {{ value_json["cmd"]["device"]["reg"][6]["@v"] }} unit_of_measurement: "°C" ### Odczyt mocy dmuchawy - name: eCoal Aktualna moc dmuchawy unique_id: ecoal_aktualna_moc_dmuchawy value_template: {{ value_json["cmd"]["device"]["reg"][7]["@v"] }} unit_of_measurement: "%" ### Odczyt temperatury powrotu - name: eCoal Temperatura powrotu unique_id: ecoal_temperatura_powrotu value_template: {{ value_json["cmd"]["device"]["reg"][8]["@v"] }} unit_of_measurement: "°C" ### Odczyt temperatury spalin - name: eCoal Temperatura spalin unique_id: ecoal_temperatura_spalin value_template: {{ value_json["cmd"]["device"]["reg"][9]["@v"] }} unit_of_measurement: "°C" ### Odczyt temperatury z czujnika Kamil - name: eCoal Temperatura czujnik Kamil unique_id: ecoal_temperatura_czujnik_Kamil value_template: {{ value_json["cmd"]["device"]["reg"][10]["@v"] }} unit_of_measurement: "°C" ### Odczyt temperatury z głowicy Kamil - name: eCoal Temperatura głowica Kamil unique_id: ecoal_temperatura_glowica_Kamil value_template: {{ value_json["cmd"]["device"]["reg"][11]["@v"] }} unit_of_measurement: "°C" A jest tak: ![]() dodane 2025-12-03 13:13Co ciekawe, stan encji raportuje poprawnie: sensor.ecoal_furnace_data_nastepnego_zasypu eCoal Furnace Data następnego zasypu 2025-12-04T18:50:07+00:00 device_class: timestamp icon: mdi:calendar-clock friendly_name: eCoal Furnace Data następnego zasypu choć (tak jak w logach), przesunięta jest o godzinę. Historia encji podaje już właściwie: ![]() dodane 2025-12-03 13:30Ok. Wystarczy wybrać inną kartę. ![]() ![]() dodane 2025-12-04 03:18Zauważyłem w logach HA: Rejestrator: homeassistant.components.mqtt.discovery Źródło: components/mqtt/discovery.py:393 integracja: MQTT (dokumentacja, Problemy) Pierwsze zdarzenie: 3 grudnia 2025 20:59:05 (4 wystąpienia) Ostatnio zalogowany: 3 grudnia 2025 20:59:05 Received message on illegal discovery topic homeassistant/sensor/ecoal_furnace/custom_1@temp/config. The topic contains non allowed characters. For more information see https://www.home-assistant.io/integrations/mqtt/#discovery-topic Received message on illegal discovery topic homeassistant/sensor/ecoal_furnace/custom_2@vtemp/config. The topic contains non allowed characters. For more information see https://www.home-assistant.io/integrations/mqtt/#discovery-topic Received message on illegal discovery topic homeassistant/sensor/ecoal_furnace/custom_21@vtemp/config. The topic contains non allowed characters. For more information see https://www.home-assistant.io/integrations/mqtt/#discovery-topic Received message on illegal discovery topic homeassistant/sensor/ecoal_furnace/custom_22@vtemp/config. The topic contains non allowed characters. For more information see https://www.home-assistant.io/integrations/mqtt/#discovery-topic |
|||
|
|
||||
|
pitaszek
|
Dziękuję
!Wolałbym formę, np. 2025-12-04 19:50 (tak jak jest w oryginale), ale już nie marudzę. I tak jest więcej niż bym się spodziewał! Jeszcze raz: dzięki !
|
|||
|
|
||||
|
pitaszek
|
Super.
Rozważ dodanie "Data następnego zasypu" i mamy wszystko. ![]() |
|||
|
|
||||
|
pitaszek
|
SUPER
!JEST ! Tak to wygląda:Pompa 1=1 Pompa 2=0 Pompa CWU=1 Poziom paliwa=53% Pozycja zaworu pom. 1=0% Pozycja zaworu pom. 2=nieznany Pozycja zaworu pom. 3=0% Szybkość wentylatora=38% Temp czujnik. 1=18,4 °C Temp. CWU=55,7 °C Temp. faktyczna CWU=60,0 °C Temp. faktyczna kotła=59,0 °C Temp. faktyczna zewnętrzna=2,0 °C Temp. głowica 1=19,7 °C Temp. kotła=58,4 °C Temp. podajnika=32,7 °C Temp. pom. 1=nieznany Temp. pom. 1=20,9 °C Temp. pom. 2=47,8 °C Temp. pom. 2=47,8 °C Temp. pom. 3=nieznany Temp. powrotu=52,6 °C Temp. spalin=91,4 °C Temp. wewnętrzna=20,9 °C Temp. zad. boilera=59,0 °C Temp. zad. CWU=nieznany Temp. zad. pom. 1=35,0 °C Temp. zad. pom. 2=35,0 °C Temp. zad. pom. 3=nieznany Temp. zad. zaworu pom. 1=nieznany Temp. zad. zaworu pom. 2=nieznany Temp. zad. zaworu pom. 3=nieznany Temp. zewnętrzna=2,0 °C Tryb automatyczny=1 Typ podajnika=retort_manual Teraz tylko popracować nad zdublowanymi encjami np: Temp. pom. 1=nieznany Temp. pom. 1=20,9 °C Temp. wewnętrzna=20,9 °C Temp. pom. 2=47,8 °C Temp. pom. 2=47,8 °C Temp. faktyczna CWU=60,0 °C Temp. faktyczna kotła=59,0 °C Temp. faktyczna zewnętrzna=2,0 °C Temp. zewnętrzna=2,0 °C Nie wiem, co miałeś na myśli "temp. faktyczna", bo mi temp faktyczna bardziej wygląda na temp zadana (w przypadku kotła, bo w przypadku temp zew. juz nie wiem... Temp wewnętrzna to to samo co temp pom. 1 itd... Dziękuje i czekamy na wersję "finał" ![]() dodane 2025-12-02 15:28Nie mogłem już edytować... Czy prośbę o dodanie "Daty kolejnego zasypu" nie potraktujesz jako "eskalację żądań"?
|
|||
|
|
||||
|
pitaszek
|
Zrobiłem aktualizację:
logi: Configuration: /data/options.json 2025-12-02T12:24:36.035Z [INFO] Configuration loaded successfully 2025-12-02T12:24:36.038Z [INFO] Device: eCoal Furnace at 192.168.1.100 2025-12-02T12:24:36.038Z [INFO] Loading configuration... 2025-12-02T12:24:36.039Z [INFO] Loading services... 2025-12-02T12:24:36.041Z [INFO] Connecting to MQTT broker... 2025-12-02T12:24:36.155Z [DEBUG] Polling eCoal data... 2025-12-02T12:24:36.156Z [INFO] Polling scheduled every 30 seconds 2025-12-02T12:24:36.156Z [INFO] eCoal Controller started successfully 2025-12-02T12:24:36.188Z [INFO] Connected to MQTT broker at mqtt://192.168.1.204:1893 2025-12-02T12:24:36.194Z [INFO] Published MQTT discovery configurations 2025-12-02T12:24:36.196Z [INFO] Subscribed to command topics: homeassistant/switch/ecoal_furnace/auto_mode/set and number control topics 2025-12-02T12:24:36.208Z [INFO] Connected to eCoal v3.5 (1.1.38.12) 2025-12-02T12:24:36.264Z [DEBUG] Fetched eCoal data successfully 2025-12-02T12:24:36.265Z [DEBUG] Published sensor data: sensor_external_temp = 1.57 2025-12-02T12:24:36.266Z [DEBUG] Published sensor data: sensor_fuel_level = 55 2025-12-02T12:24:36.266Z [DEBUG] Published sensor data: sensor_boiler_temp = 59.22 2025-12-02T12:24:36.266Z [DEBUG] Published sensor data: sensor_return_temp = 52.38 2025-12-02T12:24:36.266Z [DEBUG] Published sensor data: sensor_dhw_temp = 55.70 2025-12-02T12:24:36.266Z [DEBUG] Published sensor data: sensor_flue_gas_temp = 95.24 2025-12-02T12:24:36.266Z [DEBUG] Published sensor data: sensor_blower_speed = 38 2025-12-02T12:24:36.267Z [DEBUG] Published sensor data: sensor_auto_mode = 1 2025-12-02T12:24:36.267Z [DEBUG] Published sensor data: sensor_pump_1 = 1 2025-12-02T12:24:36.267Z [DEBUG] Published sensor data: sensor_pump_2 = 0 2025-12-02T12:24:36.267Z [DEBUG] Published sensor data: sensor_out_cwu = 1 2025-12-02T12:24:36.267Z [DEBUG] Published sensor data: sensor_boiler_setpoint = 59 2025-12-02T12:24:36.267Z [DEBUG] Published sensor data: sensor_feeder_temp = 32.06 2025-12-02T12:24:36.268Z [DEBUG] Published sensor data: sensor_internal_temp = 20.98 2025-12-02T12:24:36.268Z [DEBUG] Published sensor data: sensor_t2_temp = 46.93 2025-12-02T12:24:36.268Z [DEBUG] Published sensor data: sensor_external_actual = 1.57 2025-12-02T12:24:36.268Z [DEBUG] Published sensor data: sensor_boiler_actual = 59 2025-12-02T12:24:36.268Z [DEBUG] Published sensor data: sensor_dhw_actual = 60 2025-12-02T12:24:36.268Z [DEBUG] Published sensor data: sensor_circuit1_room_temp = 20.98 2025-12-02T12:24:36.268Z [DEBUG] Published sensor data: sensor_circuit1_room_setpoint = 35.00 2025-12-02T12:24:36.268Z [DEBUG] Published sensor data: sensor_circuit1_valve_position = 0 2025-12-02T12:24:36.268Z [DEBUG] Published sensor data: sensor_circuit2_room_temp = 46.93 2025-12-02T12:24:36.269Z [DEBUG] Published sensor data: sensor_circuit2_room_setpoint = 35.00 2025-12-02T12:24:36.269Z [DEBUG] Published sensor data: sensor_circuit3_valve_position = 0 2025-12-02T12:24:36.269Z [DEBUG] Published sensor data: sensor_pod_typ = retort_manual 2025-12-02T12:24:36.270Z [DEBUG] Published number data: control_boiler_setpoint = 59 2025-12-02T12:24:36.270Z [DEBUG] Published number data: control_dhw_setpoint = 60 2025-12-02T12:24:36.270Z [DEBUG] Published number data: control_circuit_1_room_setpoint = 35.00 2025-12-02T12:24:36.270Z [DEBUG] Published number data: control_circuit_2_room_setpoint = 35.00 2025-12-02T12:24:36.270Z [DEBUG] eCoal data updated successfully 2025-12-02T12:24:36.271Z [INFO] Fetching custom entries 2025-12-02T12:24:36.277Z [DEBUG] Published sensor data: custom_1@temp = 18.37 2025-12-02T12:24:36.277Z [DEBUG] Published sensor data: custom_21@vtemp = 19.7 2025-12-02T12:24:36.277Z [DEBUG] Custom entries updated successfully 2025-12-02T12:25:06.161Z [DEBUG] Polling eCoal data... 2025-12-02T12:25:06.204Z [DEBUG] Fetched eCoal data successfully 2025-12-02T12:25:06.204Z [DEBUG] Published sensor data: sensor_external_temp = 1.52 2025-12-02T12:25:06.205Z [DEBUG] Published sensor data: sensor_fuel_level = 55 2025-12-02T12:25:06.205Z [DEBUG] Published sensor data: sensor_boiler_temp = 59.32 2025-12-02T12:25:06.205Z [DEBUG] Published sensor data: sensor_return_temp = 52.39 2025-12-02T12:25:06.205Z [DEBUG] Published sensor data: sensor_dhw_temp = 55.70 2025-12-02T12:25:06.205Z [DEBUG] Published sensor data: sensor_flue_gas_temp = 95.69 2025-12-02T12:25:06.205Z [DEBUG] Published sensor data: sensor_blower_speed = 0 2025-12-02T12:25:06.205Z [DEBUG] Published sensor data: sensor_auto_mode = 1 2025-12-02T12:25:06.206Z [DEBUG] Published sensor data: sensor_pump_1 = 1 2025-12-02T12:25:06.206Z [DEBUG] Published sensor data: sensor_pump_2 = 0 2025-12-02T12:25:06.206Z [DEBUG] Published sensor data: sensor_out_cwu = 1 2025-12-02T12:25:06.206Z [DEBUG] Published sensor data: sensor_boiler_setpoint = 59 2025-12-02T12:25:06.206Z [DEBUG] Published sensor data: sensor_feeder_temp = 32.07 2025-12-02T12:25:06.206Z [DEBUG] Published sensor data: sensor_internal_temp = 20.97 2025-12-02T12:25:06.206Z [DEBUG] Published sensor data: sensor_t2_temp = 46.87 2025-12-02T12:25:06.206Z [DEBUG] Published sensor data: sensor_external_actual = 1.52 2025-12-02T12:25:06.207Z [DEBUG] Published sensor data: sensor_boiler_actual = 59 2025-12-02T12:25:06.207Z [DEBUG] Published sensor data: sensor_dhw_actual = 60 2025-12-02T12:25:06.207Z [DEBUG] Published sensor data: sensor_circuit1_room_temp = 20.97 2025-12-02T12:25:06.207Z [DEBUG] Published sensor data: sensor_circuit1_room_setpoint = 35.00 2025-12-02T12:25:06.207Z [DEBUG] Published sensor data: sensor_circuit1_valve_position = 0 2025-12-02T12:25:06.208Z [DEBUG] Published sensor data: sensor_circuit2_room_temp = 46.87 2025-12-02T12:25:06.208Z [DEBUG] Published sensor data: sensor_circuit2_room_setpoint = 35.00 2025-12-02T12:25:06.208Z [DEBUG] Published sensor data: sensor_circuit3_valve_position = 0 2025-12-02T12:25:06.208Z [DEBUG] Published sensor data: sensor_pod_typ = retort_manual 2025-12-02T12:25:06.208Z [DEBUG] Published number data: control_boiler_setpoint = 59 2025-12-02T12:25:06.208Z [DEBUG] Published number data: control_dhw_setpoint = 60 2025-12-02T12:25:06.208Z [DEBUG] Published number data: control_circuit_1_room_setpoint = 35.00 2025-12-02T12:25:06.208Z [DEBUG] Published number data: control_circuit_2_room_setpoint = 35.00 2025-12-02T12:25:06.208Z [DEBUG] eCoal data updated successfully konfig: entity_language: pl ecoal_host: 192.168.1.100 ecoal_username: xxxxxx ecoal_password: xxxxxx mqtt_broker: 192.168.1.204 mqtt_port: 1893 mqtt_username: xxxxxx mqtt_password: xxxxxx mqtt_topic_prefix: homeassistant device_name: eCoal Furnace poll_interval: 30 log_level: debug tempMappings: 1@temp="Temp czujnik. 1" vtempMappings: 21@vtemp="Temp. głowica 1" Cały czas jest 40 encji, ale brakuje głowicy i czujnika radiowego. |
|||
|
|
||||
|
pitaszek
|
Brakuje 1@temp i 21@vtemp http://192.168.1.100/getregister.cgi?device=0&1@temp&21@vtemp&2@temp&22@vtemp <cmd status="ok"> <device id="0"> <reg vid="1" tid="temp" v="18.15" min="0.00" max="0.00"/> <reg vid="21" tid="vtemp" v="19.50" min="0.00" max="0.00"/> <reg vid="2" tid="temp" status="outdated_data"/> <reg vid="22" tid="vtemp" status="outdated_data"/> </device> </cmd> http://192.168.1.100/getregister.cgi?device=0&temp&vtemp <cmd status="ok"> <device id="0"> <reg vid="0" tid="temp" status="not_found"/> <reg vid="0" tid="vtemp" status="not_found"/> </device> </cmd> |
|||
|
|
||||
|
pitaszek
|
Logi po aktualizacji bety:
Starting eCoal Furnace Controller... Configuration: /data/options.json 2025-12-01T20:39:53.426Z [INFO] Configuration loaded successfully 2025-12-01T20:39:53.431Z [INFO] Device: eCoal Furnace at 192.168.1.100 2025-12-01T20:39:53.431Z [INFO] Loading configuration... 2025-12-01T20:39:53.432Z [INFO] Loading services... 2025-12-01T20:39:53.436Z [INFO] Connecting to MQTT broker... 2025-12-01T20:39:53.572Z [INFO] Polling scheduled every 30 seconds 2025-12-01T20:39:53.576Z [INFO] eCoal Controller started successfully 2025-12-01T20:39:53.611Z [INFO] Connected to eCoal v3.5 (1.1.38.12) 2025-12-01T20:39:53.633Z [INFO] Connected to MQTT broker at mqtt://192.168.1.204:1893 2025-12-01T20:39:53.642Z [INFO] Published MQTT discovery configurations 2025-12-01T20:39:53.647Z [INFO] Subscribed to command topics: homeassistant/switch/ecoal_furnace/auto_mode/set and number control topics 2025-12-01T20:39:53.726Z [INFO] Fetching custom entries 2025-12-01T20:39:53.733Z [WARN] Custom entry 2@vtemp has no value, skipping. Got: {"vid":"2","tid":"vtemp","status":"not_found"} 2025-12-01T20:39:53.733Z [WARN] Custom entry 22@vtemp has no value, skipping. Got: {"vid":"22","tid":"vtemp","status":"outdated_data"} 2025-12-01T20:40:23.617Z [INFO] Fetching custom entries 2025-12-01T20:40:23.623Z [WARN] Custom entry 2@vtemp has no value, skipping. Got: {"vid":"2","tid":"vtemp","status":"not_found"} 2025-12-01T20:40:23.623Z [WARN] Custom entry 22@vtemp has no value, skipping. Got: {"vid":"22","tid":"vtemp","status":"outdated_data"} 2025-12-01T20:40:53.619Z [INFO] Fetching custom entries 2025-12-01T20:40:53.625Z [WARN] Custom entry 2@vtemp has no value, skipping. Got: {"vid":"2","tid":"vtemp","status":"not_found"} 2025-12-01T20:40:53.626Z [WARN] Custom entry 22@vtemp has no value, skipping. Got: {"vid":"22","tid":"vtemp","status":"outdated_data"} Starting eCoal Furnace Controller... Configuration: /data/options.json 2025-12-01T20:41:02.591Z [INFO] Configuration loaded successfully 2025-12-01T20:41:02.593Z [INFO] Device: eCoal Furnace at 192.168.1.100 2025-12-01T20:41:02.593Z [INFO] Loading configuration... 2025-12-01T20:41:02.594Z [INFO] Loading services... 2025-12-01T20:41:02.596Z [INFO] Connecting to MQTT broker... 2025-12-01T20:41:02.723Z [INFO] Polling scheduled every 30 seconds 2025-12-01T20:41:02.723Z [INFO] eCoal Controller started successfully 2025-12-01T20:41:02.743Z [INFO] Connected to MQTT broker at mqtt://192.168.1.204:1893 2025-12-01T20:41:02.749Z [INFO] Published MQTT discovery configurations 2025-12-01T20:41:02.751Z [INFO] Subscribed to command topics: homeassistant/switch/ecoal_furnace/auto_mode/set and number control topics 2025-12-01T20:41:02.762Z [INFO] Connected to eCoal v3.5 (1.1.38.12) 2025-12-01T20:41:02.815Z [INFO] Fetching custom entries 2025-12-01T20:41:02.822Z [WARN] Custom entry 2@vtemp has no value, skipping. Got: {"vid":"2","tid":"vtemp","status":"not_found"} 2025-12-01T20:41:02.823Z [WARN] Custom entry 22@vtemp has no value, skipping. Got: {"vid":"22","tid":"vtemp","status":"outdated_data"} 2025-12-01T20:41:32.770Z [INFO] Fetching custom entries 2025-12-01T20:41:32.776Z [WARN] Custom entry 2@vtemp has no value, skipping. Got: {"vid":"2","tid":"vtemp","status":"not_found"} 2025-12-01T20:41:32.777Z [WARN] Custom entry 22@vtemp has no value, skipping. Got: {"vid":"22","tid":"vtemp","status":"outdated_data"}Te zdublowane encje były również w wersji oficjalnej. (chodzi mi o encje które występowały pod róznymi nazwami, ale dotyczyły tego samego czujnika. Np. temp kotła i temp. bojlera)Lub np. temp pom 1=nieznany i temp pom 1=20,7 °C Terza dopiero zauważyłem, że godzina w logach jest opóźniona o 1h dodane 2025-12-01 20:49Po aktualizacji bety niektóre są faktycznie zdublowane: ![]() EDYTA: Fizycznie mam tylko jeden czujnik radiowy i jedną głowicę. Po aktualizacji bety, z automatu dopisała się druga głowica i drugi czujnik. |
|||
|
|
||||
|
pitaszek
|
Odinstalowałem wersję oficjalną
Zainstalowałem betę ![]() Jest 40 encji Doszły encje "Pompa CWU", "Typ podajnika" Ale nie widzę temp. głowicy i zaworu. Widzę kilka zdublowanych encji (niektóre mają status "unknown"). Nie zrozum mnie źle, moja postawa nie jest postawą roszczeniową. Wykonałeś ogromną i fantastyczną pracę, za którą jestem Ci ogromnie wdzięczny. Dałeś palec, to odgryziemy Ci rękę! ![]() Czekamy na finalną wersję, bo to co zrobiłeś - jest fantastyczne! (koniec z zakichanymi restami) i tasiemcami w plikach konfiguracyjnych) Dziękuję! ![]() ![]() |
|||
|
|
||||
|
pitaszek
|
Potwierdzam:
temp czujnik 1: 1@temp temp. głowica 1: 21@vtemp Analogicznie: temp. czujnik 2: 2@temp temp. głowica 2: 22@vtemp http://192.168.1.100/info.cgi pole "type" zawsze wyświetla (co bym nie włączył/wyłączył/przełączył): hardware type="eCoal". |
|||
|
|
||||
|
pitaszek
|
Trochę "nie ogarniam"...
Zacznijmy od prostych spraw ![]() 1. Pompa 1 pokazuje status mojej pompy CO1 2. Pompa 2 pokazuje status mojej pompy CO2 (nie CWU) 3. Rozumiem że: "Tryb automatyczny 1" oznacza tryb automatyczny (kto by się spodziewał ), "Tryb automatyczny 0" - oznacza tryb ręczny? 4. "Potrzebuję adres z pola "resource", żeby dostać nazwy wartości które podesłałeś" czy o to chodzi?: resource: http://192.168.1.100/getregister.cgi?device=0&tzew_value&fuel_level&next_fuel_time&tryb_auto_state&tcwu_value&tkot_value&twew_value&act_dm_speed&tpow_value&tsp_value&1@temp&21@vtemp |
|||
|
|
||||
|
pitaszek
|
@MTZD
Dziękuję – robota pierwsza klasa! Do pełni szczęścia brakuje mi tylko kilku smaczków, bez których nie mogę spać spokojnie :temperatury z głowicy: value_template: {{ value_json["cmd"]["device"]["reg"][11]["@v"] }} czujnika radiowego: value_template: {{ value_json["cmd"]["device"]["reg"][10]["@v"] }} statusu pompy CWU (ON/OFF) statusu kotła (ręczny / automatyczny) typu podajnika (ręczny / grupowy / eCoal) Chyba że to wszystko już jest, tylko ja jak zwykle coś popsułem. ![]() |
|||
|
|
||||
|
pitaszek
|
faco napisał » 2025-02-13 15:56 "... a zastawienie wszystkich obiegów na zaworach wraz z CWU zakończyło totalnie ten proces." Chodzi o ZAMKNIĘCIE zaworów? Mam ten sam problem. Od wody, która ścieka po ściankach kotła i gromadzi się na dole, w tym roku pojawiła się dziura w podłodze kotła i w popielniku... |
|||
|
|
||||
|
pitaszek
|
rj1972 napisał » 2024-05-25 19:40 Strona którą podajesz jest na liście zagrożeń. Zależy kto jakie ma zabezpieczenia. Raczej uważaj. Karolinka tylko w PGG. dzięki ![]() |
|||
|
|
||||
|
pitaszek
|
Miał ktoś doświadczenie z tym sklepem: Karolinka - skleppgg.com
Cena niższa o 50zł (bez żadnych kodów rabatowych) i dostawa gratis. Czy to jest ta sama Karolinka co w sklep.pgg.pl ? Chyba, że coś popierniczyłem... |
|||
|
|
||||
|
pitaszek
|
Jak ręcznie włączyć pompy?
W lato używam pomp do schładzania zasobnika CWU - używam kolektorów słonecznych. Najpierw pompa CWU, a jak nie wystarczało to włączałem CO1. Taka możliwość jest mi niezbędna! Panowie z ES: planujecie taką możliwość? |
|||
|
|
||||
|
pitaszek
|
@Grzes484
Z BT2 odczytałem dopisując w resource (na końcu): &1@temp Zadziałało! Analogicznie z głowicy: &21@vtemp W związku z tym, że mam jedną głowicę i jeden BT4B, jest to pierwsza głowica (1) i pierwszy czujnik (21). U Ciebie ta numeracja może być inna, ale zasada jest ta sama: głowice zaczynają się od 1, a czujniki od 21 (chyba ).Tak teraz u mnie wygląda resource: resource: http://192.168.1.100/getregister.cgi?device=0&tzew_value&fuel_level&next_fuel_time&tryb_auto_state&tcwu_value&tkot_value&twew_value&act_dm_speed&tpow_value&tsp_value&1@temp&21@vtemp ![]() A tak to wygląda w HA: ![]() |
|||
|
|
||||
|
pitaszek
|
Siemka
![]() Już kilka miesięcy podchodzę (jak pies do jeża) do tematu integracji z Home Assistant - i nie pomyliłem się! Po wklejeniu do pliku configuration.yaml i restarcie HA #### eCoal sensor # Odczyt temperatury zewnętrznej - platform: rest name: ecoal_temp_zew #friendly_name: ecoal Temperatura zewnętrzna resource: http://root:root@192.168.1.100/getregister.cgi?device=0&tzew_value value_template: {{ value_json["cmd"]["device"]["reg"]["@v"] }} unit_of_measurement: "°C" device_class: temperature # Odczyt temperatury wewnętrznej - czujnik pieca - platform: rest name: ecoal_temp_wew #friendly_name: Temperatura wewnętrzna resource: http://root:root@192.168.1.100/getregister.cgi?device=0&twew_value value_template: {{ value_json["cmd"]["device"]["reg"]["@v"] }} unit_of_measurement: "°C" device_class: temperature # Odczyt poziomu paliwa - platform: rest name: ecoal_poziom_paliwa #friendly_name: Poziom paliwa resource: http://root:root@192.168.1.100/getregister.cgi?device=0&fuel_level value_template: {{ value_json["cmd"]["device"]["reg"]["@v"] }} unit_of_measurement: "%" # Odczyt daty następnego zasypu - platform: rest name: ecoal_data_nast_zasypu resource: http://root:root@192.168.1.100/getregister.cgi?device=0&next_fuel_time value_template: {{ value_json["cmd"]["device"]["reg"]["@v"] | int | timestamp_custom("%Y-%m-%d %H:%M") }} # Odczyt temperatury CWU - platform: rest name: ecoal_temp_cwu_aktualna #friendly_name: Temp CWU aktualna resource: http://root:root@192.168.1.100/getregister.cgi?device=0&tcwu_value value_template: {{ value_json["cmd"]["device"]["reg"]["@v"] }} unit_of_measurement: "°C" # Odczyt temperatury kotła - platform: rest name: ecoal_temp_kotla #friendly_name: Temperatura kotła resource: http://root:root@192.168.1.100/getregister.cgi?device=0&tkot_value value_template: {{ value_json["cmd"]["device"]["reg"]["@v"] }} unit_of_measurement: "°C" device_class: temperature # Odczyt trybu pracy kotła - platform: rest name: ecoal_tryb_pracy_state #friendly_name: Tryb pracy resource: http://root:root@192.168.1.100/getregister.cgi?device=0&tryb_auto_state value_template: {{ value_json["cmd"]["device"]["reg"]["@v"] }} - platform: template sensors: ecoal_tryb_pracy: friendly_name: "Tryb pracy" value_template: >- {% if is_state("sensor.ecoal_tryb_pracy_state", "1") %} Automatyczny {% elif is_state("sensor.ecoal_tryb_pracy_state", "0") %} Ręczny {% else %} Alarmowy {% endif %} jedyną encją która się pojawia to: "sensor.ecoal_tryb_pracy", a i tak wynik jest newłaściwy, bo pokazuje tryb alarmowy (a powinien automatyczny?). Co mam poprawić aby zobaczyć pozostałe encje? dodane 2023-11-05 15:58Ok. Po trzech dniach kombinowania doszedłem do tego. Sposób z pierwszego posta u mnie nie działa. Zadziałał ten: ![]() Tylko wartość: "resource" to teraz strasznie długi tasiemiec... Czy można go jakoś skrócić? |
|||
|
|
||||
|
pitaszek
|
leON22 napisał » 2023-10-17 09:03 Witam, co znaczy "od jakiegoś czasu"? Wg mnie przyczyną może być brak zaznaczonego "ptaszka" - domyślne paliwo przy kolejnym zasypie w statystykach. Sprawdź ten drugi zakup, czy ma zaznaczoną tę opcję Alarm pojawił się w dniu zakończeniu sezonu 19.04.2023 (kocioł został przełączony w tryb "ręczny"). Mimo 10% stanu opału wystąpił alarm. Trwał 6 sek. i ustąpił samoczynnie. Ponownie pojawił się 12.10.2023 (ale zauważyłem go dopiero wczoraj). Zrobiłem "fałszywy" zasyp i na razie alarm nie występuje. Z zasypami jest ok. |
|||
|
|
||||
|
pitaszek
|
Cześć.
Od jakiegoś czasu pojawił się alarm "Pusty zasobnik". Piec stoi od ostatniego okresu grzewczego nieużywany. Kasowanie alarmu nic nie daje - alarm wskakuje na nowo. Był już post na ten temat: link ale tam problemem była również błędna data kolejnego zasypu. U mnie data zasypu również jest błędna (zawsze obecna data i godzina) - mimo że sterownik podaje jeszcze 10%, a czas do opróżnienia to 414min. Proszę o pomoc - kocioł użytkują starsi ludzie, a sezon już za pasem. dodane 2023-10-17 08:20 ![]() |
|||